Typical Applications
Model No | PB-2590-SMB-10.2 |
---|---|
Voltage Range |
Series Mode: 20.0V min.; 28.8V nom.; 33.6V max.
Parallel Mode: 10.0V min.; 14.4V nom.; 16.8V max. |
Nominal Capacity |
Series Mode: 10.2 Ah @ 500mA @ 23°C (74°F)
Parallel Mode: 20.4 Ah @ 1.0A @ 23°C (74°F) |
Maximum Discharge |
Series Mode: 10.0 A continuous @ 23°C (74°F) (per section)
Parallel Mode: 20.0 A continuous @ 23°C (74°F) |
Max. Pulse Discharge |
Series Mode: 22.5A for 10 mSec; 18.0 A for 5 seconds @ 23°C (74°F)
Parallel Mode: 45A for 10 mSec; 36.0 A for 5 seconds @ 23°C (74°F) |
Energy | 294 Wh |
Energy Density | 222 Wh/kg, 358 Wh/l |
Weight | 1406 grams / 1.4Kg (3.1 lbs.) |
Cycle Life | > 300 cycles @ C/5 to 80% of initial capacity @ 100% depth of discharge |
Operating Temperature | -30°C to +70°C (-22°F to +158°F) |
Storage Temperature | -20° C to +50° C (-4°F to +122°F) |
Self-Discharge | < 3% per month @ 25°C (77°F) |
Housing | Hard plastic, tan, lusterless, UL 94 V-0, NORYL |
Mating Connector | Floating type per U.S. Army DQWG# SC-C-179495 |
Communications |
|
Contacts | Copper alloy with gold plating over nickel plating |
State of Charge Indicator | 2 Separate, 5 Segment, LCD Displays |
Safety | See Safety Data Sheet - SDS066 |
Transportation | See Safety Data Sheet - SDS066 |
Harmonized Tariff Code | 8507.60.0020 |
Battery Charging | Charge each section at constant voltage of 16.8 Volts in a temperature range of 0°C to +45°C (+32°F to +113°F), limiting current to 3.0 amps until current declines to 200mA. Both sections can be charged in parallel. |
Charging Method | This battery should be charged using a constant current/constant voltage (CC/CV) charging method. |